FireKing Safes, Files, and CCTV
General Support Information Find out what Products are available for your type of business Product Technical Information Safes Technical Support - AuditLok XL Simulator

AuditLok XL Simulator - Door Configuration

CONTINUE

Set Door Configuration:
If the door selected is behind another door, press the top Select button shows the correct door number next to PREREQ. Door 1 is always the outer door and should have no prerequisite. If you require two users to log in every time to open the door press the top Select button until DUAL is set to YES, otherwise leave this at NO. Use the second Select button to tell the electronics whether the door actually exists on the safe. If the door does not physically exist then EXISTS should be set to NO so the false door is not available on user menus. SENSORS may be set to NONE, 1, or 1 & 2. The outer door should have two sensors. The setting is changed by override for customers when a door sensor fails (and changed back after the sensor is repaired). Use Left Scroll or Right Scroll buttons to edit other doors. Select DONE to accept changes.

Press ESC to exit.